An AGV wheel drive needs one number before it can move: where the wheel points right now, not where it was at switch-off and not where a homing routine would put it. An absolute magnetic sensor answers that on the first frame after power-up, which is why the steering axis of a warehouse robot is usually a magnet and a Hall die rather than an optical encoder.
Inside that category there are three rungs, which are not three price points on one part. They are three answers to who owns the signal. The lowest hands the host an analog voltage and lets its ADC decide what it means. The middle hands over a digital frame with a checksum. The top hands over a frame plus a transfer curve the sensor has been taught to follow.
The MLX90366LVS-ADU-253 sits on the middle rung, with one caveat that belongs up front: the datasheet marks this option code as not recommended for new design (p. 4). The rung is real and the silicon is documented. The die version is frozen. What follows is where the rung sits, what it buys, and which code to write if the design starts today.
A tier map for the category
Three requirements produce three rungs. A wheel drive that only needs a coarse steering angle, and already has a spare ADC channel next to a 5 V reference, can use the analog rung. A drive whose motor controller already speaks SENT wants the digital rung. A drive with an off-axis magnet, a long stroke, or a specification that spans a motor housing's full temperature range needs the top rung. An off-axis magnet on the middle rung is unsuitable, because three-point linearisation cannot bend the curve far enough.
| Rung | Output the host receives | What the host must add | Where it fits |
|---|---|---|---|
| Analog | ratiometric voltage or PWM | ADC channel, reference, filtering | low-cost steering feedback, short cable |
| SENT | 12-bit angle in a framed message | SENT receiver or timer capture | wheel drive with a SENT-capable controller |
| SENT with linearisation | same frame, taught transfer curve | the same receiver, more end-of-line points | off-axis magnet, linear stroke, wide temperature |
The rungs share a sensing principle, so the magnet, the air gap and the tolerances are common problems. What changes is how much of the answer the sensor owns.
What separates the rungs
The first separator is signal integrity, and it decides more AGV designs than any accuracy figure. An analog output leaves the die as a voltage between the diagnostic bands, and everything between sensor and ADC adds to it: cable, connector, ground offset between hub and controller, and inverter switching noise a few centimetres away. A SENT frame carries the same quantity as a time-encoded message with a 12-bit payload, an 8-bit rolling counter, an inverted copy and a CRC (p. 20). The receiver reconstructs the angle or rejects the frame, with no middle state where a noisy reading looks plausible.
The second separator is the transfer curve. Every part is programmable, but the option code sets how much curve is available. The U options carry three-point linearisation, which places the endpoints and one middle point and interpolates between them. The V, S and X options carry seventeen-point piecewise-linear correction, and the X option adds thermal offset correction on the output (p. 5). Three points match a rotary magnet on the shaft axis, where the field is close to sinusoidal and the error left over is a shallow bow. Seventeen points are for geometries where the curve is not a bow at all: an off-axis magnet on a steering arm, or a linear stroke read at an angle.
The third separator is mechanical, and it is the one that changes the BOM. The DMP-4 package carries its own capacitors, 100 nF and 10 nF in the 25x configuration (p. 36), so the sensor can be moulded into a housing with three wires leaving it and no board inside. Those capacitors are X8R ceramic, glued rather than soldered, and rated 50 V (p. 36). A sensor that needs no PCB can survive potting, and potting is how a hub module survives washdown and vibration.
The fourth separator is diagnostics. The status nibble in each frame carries a channel error flag, and when the error-reporting parameter is set the 12-bit payload is replaced by an error code (p. 21). Behind it sit a watchdog with a 118 ms window, an EEPROM CRC checked every 10 ms and a ROM checksum every 800 ms (p. 9, p. 33).
Why this part earns its rung
The order code decodes into a specific engineering position. ADU-253: the U says three-point linearisation, the 25 says the 100 nF and 10 nF capacitor set, and the final 3 says trim-and-form in the STD2 2.54 mm outline (p. 5, p. 36). The D is the part that matters for a new programme, and it means the die version is not recommended for new design (p. 4).
| Parameter | Value | Datasheet location |
|---|---|---|
| Output | SENT, per SAE J2716-2010 | p. 1, p. 20 |
| Angle payload | 12 bit | p. 20 |
| Frame period | 882 µs | p. 9 |
| Tick time | 3 µs | p. 9 |
| Latency, filter enabled | 1745 µs | p. 9 |
| Supply voltage | 4.5 V to 5.5 V | p. 8 |
| Supply current | 6 mA typical, 10 mA maximum | p. 8 |
| ADC resolution | 15 bits | p. 12 |
| Intrinsic linearity, XY | ±1° | p. 12 |
| Field range, BX and BY | 70 mT | p. 13 |
| Field range, BZ | 126 mT | p. 13 |
| Minimum field norm | 20 mT | p. 13 |
| Ambient range | -40 °C to +150 °C | p. 5 |
| Qualification | AEC-Q100 | p. 1 |
| EEPROM endurance | 1000 write cycles at 125 °C | p. 33 |
| Built-in capacitors, 25x | 100 nF, 10 nF, 100 nF, 100 nF | p. 36 |
| Package | DMP-4 | p. 5 |
Three of those lines decide the fit. The 882 µs frame (p. 9) sets how often the angle arrives, and with the recommended filter the field-to-frame latency is 1745 µs (p. 9). A steering axis moves far slower than that, so the loop closes comfortably. The 20 mT minimum field norm (p. 13) and the 70 mT ceiling on the in-plane components (p. 13) bracket the magnet: too far and the signal-to-noise ratio falls, too close and the integrated concentrator saturates and linearity degrades.
The third line is the EEPROM figure. One thousand write cycles at 125 °C (p. 33) is calibration endurance, not data-logging endurance. End-of-line calibration writes the curve once, and any rework spends from the same budget. A line that recalibrates three times per unit for yield reasons will eat that allowance in a bad week. The datasheet gives ESD precautions but no HBM or CDM figure (p. 37), so treat the module connector as the boundary and protect on the cable side.
The step in either direction
Upward, the step is the AEX-253 option, which keeps the same 25x capacitor set and the same trim-and-form digit but carries seventeen-point linearisation plus thermal offset correction (p. 5). Nothing on the board changes, because the package and pinout are the same DMP-4. What changes is the end-of-line procedure: seventeen points instead of three, and a temperature step if the offset correction is to be calibrated rather than left at default. Order that rung when the magnet sits off the shaft axis, when the travel is a stroke rather than a rotation, or when the specification keeps the module at the top of the ambient range for long periods.
Sideways, the step is AEU-253. It is the same three-point option, the same capacitor set and the same outline, listed in the same table without the not-recommended note (p. 4). For a programme starting now, that is the order code to write into the BOM, and it is the reason this article can be useful about a part that is closing rather than opening.
Downward, the step is an analog-output sensor from the previous generation. The MLX90316KDC-BCG-000 offers a ratiometric analog output, PWM and SPI from a SOIC-8 package, with 12-bit angular resolution and a 15-bit ADC in slow mode (per its own datasheet). It suits a controller with a spare ADC channel and no SENT receiver, at less receiver cost. What the host gives up is the frame: no CRC, no rolling counter, no inverted copy. The MLX90316KDC-BDG-100 is the same die with the SPI option, which restores a digital path but adds a chip select and a clock line. Moving to the DMP-4 is a mechanical redesign rather than a drop-in swap, because the sensor leaves the board.
Two more members matter for a drive with a safety function. The MLX90316EGO-BCG-000 puts two dice in a TSSOP-16 with at least 4 MΩ of isolation between them (per its own datasheet), which is the redundancy answer when one channel is not enough. The MLX90316KDC-BCG-200 and MLX90316KDC-BCG-300 are pre-programmed analog and digital variants, for builds that want no calibration step. The MLX90316EDC-BCG-000 and MLX90316EGO-BDG-100 cover the narrower -40 °C to +85 °C temperature code for indoor AGVs.
Frequently asked questions
Can I move to seventeen-point linearisation without a board change?
Yes, if the package and capacitor set stay the same. The AEX-253 and AEV-253 options use the same DMP-4 outline and the same 25x capacitor configuration as this part (p. 5, p. 36). The pinout does not move, so the cable run and potting tool are unaffected. What changes is the programming file and the number of end-of-line calibration points, a production task, not a hardware one.
What do I lose by dropping to an analog sensor?
You lose the frame. An analog output carries the angle as a voltage between the diagnostic bands, and the host has to trust its ADC, its reference and its ground. A SENT frame carries a CRC, a rolling counter and an inverted copy (p. 20), so a corrupted reading is detected rather than averaged in. You also lose the error code that replaces the angle when a diagnostic fires (p. 21).
Which option codes does this package carry?
The DMP-4 package in the L temperature code covers both capacitor sets and both linearisation depths: the 25x and 46x configurations, three-point and seventeen-point curves, and thermal offset correction on the X options (p. 4, p. 5, p. 36). The trim-and-form digit selects the outline, from STD1 1.27 mm through STD4 2.54 mm (p. 5). Packing is reel only, face-up or face-down, under the RE and RX codes (p. 4).
What should procurement ask before quoting?
Ask which option code is being ordered, because the letters after LVS decide the linearisation depth, the capacitor set and the outline, and they are not interchangeable on a calibrated unit (p. 5). Ask for the packing form, since the table lists only reel options (p. 4). And ask for the lifecycle position in writing: this datasheet flags the ADx options as not recommended for new design (p. 4), so a multi-year programme should be quoted on AEU or AEX.
Sourcing note
The MLX90366LVS-ADU-253 is a four-terminal DMP-4 absolute angle sensor with a SENT output and a twelve-bit angle payload. It carries 100 nF and 10 nF built-in capacitors, a three-point linearisation curve, and AEC-Q100 qualification over -40 °C to +150 °C (p. 1, p. 5). This option code carries a not-recommended-for-new-design flag (p. 4), so quotes for new builds should reference AEU-253 for the same function or AEX-253 for the linearised version.
For analog or SPI interfaces, the MLX90316EDC-BCG-000, MLX90316KDC-BCG-000, MLX90316KDC-BDG-100, MLX90316KDC-BCG-200, MLX90316KDC-BCG-300 and MLX90316EGO-BDG-100 cover the lower rung in SOIC-8 or TSSOP-16. The MLX90316EGO-BCG-000 is the dual-die variant when redundancy is specified, and AEU-253 is the alternative order code for the same function.
Mandu Electronics quotes against the full ordering code, including the option and packing fields, and can supply the ADU part for existing builds alongside the AEU and AEX versions for new ones. The datasheet states no MOQ or lead time, so confirm both against your annual volume. Send the complete option code to [email protected] or through the contact page for a quote.